Transmitter (Single Sensor Units)—Product Data 900 MHz
14
WI-I/O-9-K
Technical Data
Inputs:
Digital:
Pulse:
Up/Down Pulse Count
Pulse Rate
Analog:
resolution
accuracy
sample time configurable
transducer warm-up time configurable
analog value transmitted on change of input signal or time
elapsed since last transmission,
change sensitivity configurable
update time configurable
Setpoint Status
Power Supply
Power consumption @12VDC
Power consumption during radio transmission (50 - 100 msec)
Analog loop supply internally generated
Internal monitoring of supply low voltage status
Power consumption increases for pulse inputs > 10Hz.
Serial Port
RS232
General Data
Operating Temperature
Humidity
EMC Standards
Approvals
Mounting
LED indication
frequency hopping spread spectrum
Transmit power
Maximum line of sight range
Receiver data sensitivity
Data rate
Antenna connector
Dimensions mm (in)
Ordering Data
Battery Pack (optional)
Plug and Lead-1 meter
two digital/pulse inputs, suitable for voltage free contacts / NPN, or voltage input 0-1 VDC on / >3 VDC off
status transmission on change of input signal and on time elapsed since last transmission - update time period 10 sec - 5days, a
separate update time can be configured when the discrete input is “on”
Pulse rate up to 1000 Hz, 3 msec on time. Pulse counted as 16 bit register with a 16 bit overflow register (total count 32 bit).
Transmissions occur when count change exceeds configured increase, or on time elapsed since last transmission; update
time 10 sec - 5 days ; change transmissions may be suspended if increase exceeds a configured value to reduce radio traffic.
the two pulse inputs may be configured to a single count, to suit quadrature or incremental shaft encoder transducers.
calculated from rate of pulse input and treated as an internal analog input. Configurable scaling. Transmitted as per analog input.
one analog input 0-25 mA (4-20mA, 0-10mA)
0-10V also available “floating” differential input
12 bit
< 0.1 % measurement continuous or sampled
1 min - 5 days
0.5-127 sec
0.7-75%
0.1min - 5 days
high and low setpoints generate internal digital status
setpoint status sets (on) when analog value < low setpoint and resets (off) when analog value > high setpoint
status transmitted as per digital input
quiescent (sleep mode) 120µA, operating mode 10mA + analog loop
300mA @ 1W, 220µA @ 500mW
100mA @ 100mW, 50mA @ 10mW
Yes
may be transmitted to remote modules as an “input”
DB9 female DCE, used for configuration and diagnostics
-40 to 60°C (-40 to 140°F)
0 - 99% RH
compliant 89/336 EEC, EN 300 683, AS3548, FCC Part 15
Housing - IP66 NEMA4; FCC Part 15.247, RS210, CSA Class 1, Div 2
Radio TX, Operation OK
902-928MHz, sub-bands available
1 W
20miles (4W ERP), 15 km (1W ERP)
108 dBm
19.2 Kbs with forward error correction
SMA coaxial
150 x 64 x 36 (5.1 x 2.5 x 1.4)
Type Part No.
WI-I/O-9-K 6720005004
WI-BP-I/O-9-K 6720005112
WI-PLI-9-K 6720005113