Transmitter (Single Sensor Units)—Introduction
WI-I/O 9-K Transmitter (Single Sensor Units)
Frequency hopping spread spectrum 902-928 MHz 1W, license-free USA/Canada
Configurable sub-bands license-free Mexico, South America, Australia/NZ, Hong Kong
The Single Sensor Wireless I/O range of products is suitable for connecting to a single sensor or group of sensors and provides an
economical solution for remote monitoring systems. Capable of being powered by battery-only supplies, these products are partic-
ularly suitable where power is not available.
Features
Input-only unit - two digital/pulse one analog
Networks with Multi-I/O and Gateway units
Analog Loop Supply for field devices
Sensor signals (inputs) are transmitted to a Multi-I/O module where the signals are re-created as output signals,
or passed via serial or Ethernet data bus to a host device such as a PLC or SCADA system.
Extremely low power consumption by reverting to “sleep” mode
Multiple power supply options including battery-only supply
Weatherproof IP66 / NEMA 4 enclosures
Class 1 Div 2 hazardous areas approval (USA/Canada)
Up to 3000 wireless units per network
Any input on any unit can be wirelessly linked to any output on any unit. Inputs can be linked to multiple outputs.
Peer-to-peer communications. Exception reporting. Reliable self-checking messages. Highly secure data encryption.
Multi-hop repeater functions - up to 5 intermediate units can be configured in any input-output link
External inputs plus internally calculated values - analog setpoint status,
pulse rate and pulse total, power supply voltage, power supply alarm
Setpoint status generated by comparing analog input to high and low setpoints.
Pulse inputs generate separate pulse count value and a pulse rate value.
Pulse rates are treated as internal analog registers with a configurable maximum value.
Power supply generates internal I/O values that can be transmitted–
low normal supply voltage status, low battery voltage status and battery voltage (analog)
Can connect to up/down counter transducers such as shaft-encoders
Easily configured to repeat the transmission several times to ensure that the transmission is received correctly
Easy-to-use E-Series Windows configuration.