8 Technical data
Input
Sensor types PT 100/2 Select C, PT 100/3 Select
C according to DIN IEC 751
Input current 1.35 mA ... 1.45 mA ... 1.60 mA
Conductor resistance 50 (3-wire)
Input range -200 ... +800 °C adjustable using
DIP switches
Offset input range up to +25 % possible
Output
Current output adjustable using DIP switches
Load resistance 500
Accuracy ± 0.5 % from end value
Temperature coefficient
Measurement range
200 K 200 ppm/K (typ. 80 ppm/K)
100 K; < 200 K 250 ppm/K (typ. 100 ppm/K)
40 K; < 100 K 500 ppm/K (typ. 200 ppm/K)