Wireless I/O
Multi-I/O Units — Introduction — 900 MHz
•Shortdistanceandlongdistanceapplicationswith
license-freeandlicensedproducts
•Multi-hoprepeaterfunctions–upto5intermediate
unitscanbeconfiguredinanyinput/outputlink
•Fourversionsavailable
•Anyinputonanyunitcanbewirelesslylinkedto
anyoutputonanotherunit.Inputscanbelinkedto
multipleoutputs.
•Inputsandoutputscanbeaddedviaadditional
serialunits
•Theunitscanbepre-programmedtoconsideranalog
set-points,pulserateandpulsetotal,powersupply
voltage,powersupplyalarm
•Set-pointstatusgeneratedbycomparinganaloginputs
tohighandlowset-points.AvailableonAI1of-1units,
andAI1-4of-2units.
•Pulseinputsgenerateaseparatepulsecountvalueand
apulseratevalue.Pulseratesaretreatedasinternal
analogregisterswithaconfigurablemaximumvalue.
•Widevoltagepowersupply,withintegralUPSbattery
chargerandsolarregulator
•Powersupplygeneratesinternalsignalvalueswhich
canbetransmitted,lownormalsupplyvoltagestatus,
lowbatteryvoltagestatus,andbatteryvoltage(analog)
•Multiplecommunicationfailurediagnosticswithoutput
status.Fail-to-transmitalarmandfail-to-receivealarm
status.
•RadioreceivessignalandbackgroundRFnoise
measurement/loggingdiagnostics
•Inputmeasurementdisplayandoutput“forcing”
diagnostics
•Communicationloggingdiagnostics
•Easy-to-useE-SeriesWindowsconfigurationavailable
at www.weidmuller.ca orwww.weidmuller.com
ALARM
PLC
Gas Analyzer
Metering
Alarms
Gauges
Plant
Control
WI-I/O9MultiI/OUnits
Atransceiverisawirelessdevicemade
upofatransmitterandreceiver.Since
eachmodulecanmanagebothinputand
outputsignals,itcanbeusedtomonitor
transducersandcontrolindustrial
processes.Thismodulecanalsobeused
asarepeatertorelayanotherwireless
device’stransmission,thusincreasing
theoverallrangeofthesystem.
Typical Applications
•Wirelessjunctionboxinaprocessplanttoconnecta
largenumberofsignalstootherpartsoftheplantandto
theplantcontrolcenter
•SimpleRemoteTerminalUnit(RTU)inaSCADAsystem,
connectingsensors/instrumentation/processsignals
inpumpstations,sub-stations,pipelineregulator
stations,etc.
•Machine-to-Machinewirelessconnectivityinfactories
Features
•ClassI,Division2hazardousareasapproved
(USA/Canada);(CSAcertified)
•Multipleinputs/outputchannelsformonitoring
andcontrolfunctions
•Upto95wirelessunitspernetwork
•Eachwirelessunitcanconnecttoinput/output
expansionmodulesviaRS485multi-dropwithup
to31expansionmodulesperwirelessunit
•Sensorsignalsconnectedatonemodule;input
signalsaretransmittedtoanothermodulewhere
thesignalsarere-createdasoutputsignalsor
passedviaserialtoahostdevicesuchasaPLC
orSCADAsystem