Media converter - Value Line
Industrial Media Converter (10/100BaseT (X) to 100BaseFX)
10/100BaseT(X) auto-negotiation and auto-MDI/MDI-X
Link Fault Pass-Through (LFP)
Power failure, port break alarm by relay output
Redundant power inputs
Designed for hazardous locations (Class 1 Div. 2/Zone 2)
Technical data
Technology
Standards IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT (X) and 100BaseFX
Interfaces
Fibre Ports 100BaseFX (SC/ST connectors)
RJ45 ports 10/100BaseT(X)
DIP Switches 100BaseFX Full/Half duplex selection,
port break alarm mask
LED Indicators PWR1, PWR2, FAULT, 10/100M (TP port), 100M (Fibre port),
FDX/COL (Fibre port)
Alarm Contact One relay output with current carrying capacity
of 1 A @ 24 V DC
Optical Fibre
100BaseFX
multimode singlemode
Wavelength 1300 nm 1310 nm
Max. TX -10 dBm 0 dBm
Min. TX -20 dBm -5 dBm
RX Sensitivity -32 dBm -34 dBm
Link-Budget 12 dB 29 dB
Typical Distance 5 km
a
4 km
b
40 km
c
Saturation -6 dBm -3 dBm
a
50/125 μm, 800 MHz*km bre optic cable
b
62.5/125 μm, 500 MHz*km bre optic cable
c
9/125 μm, 3.5 PS/(nm*km) bre optic cable
Power Requirements
Input Voltage 24 V DC (12 to 48 V DC),
redundant inputs
Current consumption 0.16 A (@ 24 V)
Connection Removable terminal block
Overload Current Protection 1.1 A
Reverse Polarity Protection Present
Technical data
Housing Metal, IP 30 protection
Dimensions (W x H x D) 53.6 x 135 x 105 mm (2.11 x 5.31 x 4.13 in)
Weight 630 g
Installation TS 35
Environmental Limits
Operating temperature Standard Models: 0 to 60 °C (32 to 140 °F)
Wide Temp. Models: -40 to 75 °C (-40 to 167 °F)
Operating Humidity 5 to 95 % RH
Storage Temperature -40 to 85 °C (-40 to 185 °F)
Approvals
Security UL508, UL60950-1
EMI FCC Part 15, CISPR (EN55022) class A
EMC EN61000-4-2 (ESD), level 3
EN61000-4-3 (RS), level 3
EN61000-4-4 (EFT), level 3
EN61000-4-5 (Surge), level 2;
EN61000-4-6 (CS), level 3
EN61000-4-8
EN61000-4-11
Hazardous Location UL/cUL Class1, Division 2, Groups A, B, C,
and D, ATEX Class1, Zone 2, Ex nC IIC
Maritime DNV, GL
Freefall IEC60068-2-32
Shock IEC60068-2-27
Vibration IEC60068-2-6
MTBF (mean time between failures)
Time 401.000 hrs
Database MIL-HDBK-217F: GB 25 °C
Warranty
Warranty Period 5 years
Ordering data
Port Variants Type Operating
Temperature
Order No.
1 * RJ45, 1 * SC-Multimode IE-MC-VL-1TX-1SC
IE-MC-VLT-1TX-1SC
0 to +60 °C
-40 to +75 °C
1241400000
1286880000
1 * RJ45, 1 * ST-Multimode IE-MC-VL-1TX-1ST
IE-MC-VLT-1TX-1ST
0 to +60 °C
-40 to +75 °C
1241410000
1286890000
1 * RJ45, 1 * SC-Singlemode IE-MC-VL-1TX-1SCS
IE-MC-VLT-1TX-1SCS
0 to +60 °C
-40 to +75 °C
1241420000
1286900000
Accessories
Type Order No.
19" Rack Mounting Kit RM-KIT 1241440000