17
Fault Relay
The error relay can be used to monitor the condition of the switch. If the switch is turned off the
relay contacts are open. When power is being applied the contacts of the relay remain open until
BOTH power inputs have reached a valid level. Only then the contacts are closed. If in the ongoing
opration one of the voltage levels drops below the lower end the relay contacts are opened again. In
case the switch is operated via one power input only a connection between the DC input and ONE
of the AC inputs can be made to simulate the 2nd supply voltage. The relay is rated at 24 V with a
maximum of 30 mA.
LED
Power green power on
red invalid incoming power
LNK / ACT yellow 10 Mbit/s Link
green 100 Mbit/s Link
yellow flashes 10 Mbit/s Link traffic
green flashes 100 Mbit/s Link traffic
Status green no problem
red fault description see handbook
Console green logged in
off logged out
Auto-MDIX
The switch works with AUTO-MDIX functionality. It is possible to use crossover and straight- through
cables to connect network interfaces or other devices with the switch.