Vista de pagina 12
25
Green Numeric Error LED Meaning
LED Display
does not 1 the respective LED extraneous
light flashes or lights voltage
does not 2 all LED’s are off line interrupt
light
does not 3 LED assigned to the conductor
light respective wire lights interrupt
does not 4 LED assigned to the short circuit
light respective wire lights
does not 5 The LED at the wrong conductor
light far end flashes wiring
does not 6 LED assigned to the wrong switch
light respective wire lights setting
does not 7 no LED lights low battery
light
does not 8 LEDs of the respective split pairs
light wire pairs light
does not lighting no LED lights battery is
light bar no good
lights/ lighting no LED lights Test Box number
does not bar was not detected
light
lights no display all LED off cabling is correct
no installation
errors were found
lights a digit between all LED off display of the
1 and 9 flashes Test Box number
6. Error Indication