Weidmuller IE-ARM-U-OSPF Mini Router Manual de usuario Pagina 17

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 22
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 16
17
RRSS--223322 iinntteerrffaaccee ffoorr tthhee ""EExxtteerrnnaall"" mmooddee
The device is prepared for operation of an additional RS-232 interface. Communication channels using
this interface will be set up upon request.
FFuunnccttiioonnaall eeaarrtthhiinngg ooff tthhee MMiinnii--RRoouutteerr
For functional earthing, make a connection between the "Functional earth" terminal on bottom side of
the router and the equipotential bonding of the control cubicle.Make sure that the cross-section of the
interconnecting line does not exceed 4 mm2 (AWG12)
22..66 PPoowweerr ssuuppppllyy
Supply voltage 10 ... 35 V DC / 10 ... 24 V AC
Power (max) 4 W / 6 VA
CCaauuttiioonn
Insecure outputs. Operations on the Mini-Router only realise by qualified
employees. Use a power supply unit according to DIN EN 60742 (VDE 0551).You
secure all electrical outputs.
Vista de pagina 16
1 2 ... 12 13 14 15 16 17 18 19 20 21 22

Comentarios a estos manuales

Sin comentarios