18
22..55 PPoowweerr ssuuppppllyy
22..66 FFaauulltt rreellaayy
The error relay can be used to monitor the condition of the switch. If the switch is turned off the relay
contacts are open. When power is being applied the contacts of the relay remain open until BOTH
power inputs have reached a valid level. Only then the contacts are closed. If in the ongoing opration
one of the voltage levels drops below the lower end the relay contacts are opened again.
CCaauuttiioonn
Insecure outputs. Operations on the IE-SWx-ADVANCDED only realise by qualified
employees. Use a power supply unit according to DIN EN 60742 (VDE 0551). Se-
cure all electrical outputs.
- The switch employs Auto-MDIX technology so straight-through or crossover ca-
bles can be used to connect network interface adapters or other network devices.
- The chassis connecting serves as an additionally ground.
-The Switch does not charge the battery, so separate provisions charching are
required.
Comentarios a estos manuales